Fire-Lite ES-200X Manual: A Comprehensive Overview
This manual details the ES-200X, a modern addressable fire alarm control panel (FACP), replacing the MS-9200UDLS. It supports 198 devices and offers advanced features.
The Fire-Lite ES-200X represents a significant advancement in fire alarm control panel (FACP) technology. Designed as a direct replacement for the widely-used MS-9200UDLS, the ES-200X seamlessly integrates into existing systems while offering enhanced capabilities. This intelligent, addressable FACP is engineered for reliability and ease of use, supporting up to 198 addressable devices – a configuration of 99 detectors and 99 modules.
A key feature is its pre-installed communicator, simplifying installation and ensuring immediate connectivity. The ES-200X is suitable for a broad range of applications, bridging the gap between conventional and advanced addressable fire alarm systems. Utilizing SWIFT Tools software, programming and diagnostics are streamlined, accessible via a PC’s USB port and downloadable from firelite.com.
What is the ES-200X?
The ES-200X is Fire-Lite’s latest intelligent addressable Fire Alarm Control Panel (FACP), designed to provide comprehensive fire detection and notification. It’s a sophisticated system capable of managing a substantial number of devices, specifically up to 198 addressable points. This includes a maximum of 99 detectors and 99 modules, offering flexibility in system design.
Functioning as a central hub, the ES-200X receives signals from detection devices, processes information, and initiates appropriate responses, such as activating alarms and notifying emergency personnel. Importantly, it arrives with a pre-installed communicator, facilitating off-site monitoring. It’s a robust and versatile solution, suitable for diverse building types and sizes, and a direct upgrade path from the MS-9200UDLS.
Key Features and Benefits
The ES-200X boasts several key features enhancing fire safety and system management. Its support for 198 addressable devices allows for precise location identification of alarms, minimizing response times. The integrated communicator provides reliable off-site monitoring, ensuring prompt notification of emergencies. Compatibility with LiteSpeed intelligent AV devices expands system capabilities.
Benefits include simplified programming and diagnostics via SWIFT Tools, downloadable from firelite.com. Being a direct replacement for the MS-9200UDLS streamlines upgrades. The panel’s design accommodates applications previously served by conventional systems, offering advanced functionality in a wider range of scenarios. This results in improved reliability, faster response, and enhanced overall fire protection.

Technical Specifications
The ES-200X supports up to 198 addressable devices, including 99 detectors and 99 modules, and features a pre-installed communicator for reliable reporting.
Addressable Device Capacity
The Fire-Lite ES-200X FACP boasts a substantial addressable device capacity, making it suitable for a wide range of applications. Specifically, this panel is engineered to support a maximum of 198 addressable devices within a single system. This capacity is intelligently divided, allowing for the connection of up to 99 addressable detectors – encompassing smoke detectors, heat detectors, and other sensing devices – and an equal number of 99 addressable modules.
These modules can include relay modules, notification appliance modules, and input modules, providing flexibility in system design and configuration. This generous capacity allows for detailed zoning and precise location identification of fire events, enhancing response times and overall system effectiveness. The ES-200X’s capacity positions it as a robust solution for both small and medium-sized facilities.
Communicator Features
A key advantage of the Fire-Lite ES-200X is its integrated communicator, eliminating the need for separate installation and configuration. This pre-installed communicator facilitates reliable and swift transmission of alarm signals to a central monitoring station. It supports standard communication protocols, ensuring compatibility with a broad spectrum of monitoring services.
The integrated design streamlines the installation process and reduces potential points of failure. The communicator automatically reports alarm, supervisory, and trouble conditions, providing comprehensive system status updates. Furthermore, the ES-200X communicator is designed for efficient data transmission, minimizing communication costs and maximizing reliability in critical situations, offering peace of mind.
Power Requirements
The Fire-Lite ES-200X FACP operates on a 24VDC power supply, requiring a dedicated 24VDC power source with sufficient capacity to support all connected devices. A fully-charged 24VDC battery backup is crucial for uninterrupted operation during power outages, ensuring continuous fire protection. The panel is designed to accommodate a range of battery capacities, allowing for customized backup durations based on specific application needs.
Proper grounding is essential for safe and reliable operation. The ES-200X requires a dedicated grounding connection to minimize electrical noise and prevent damage; It’s vital to adhere to all local and national electrical codes when installing the power supply and battery backup system, guaranteeing optimal performance and longevity of the fire alarm control panel.

Installation Guide
Proper installation of the ES-200X FACP is critical; mount securely, carefully consider wiring routes, and connect addressable devices according to the provided diagrams.
Mounting the Control Panel
Securely mounting the ES-200X is paramount for reliable operation. Choose a location that is easily accessible for maintenance, yet protected from physical damage and environmental factors like excessive humidity or temperature fluctuations. The enclosure should be mounted on a solid surface capable of supporting its weight, utilizing appropriate screws and anchors.
Ensure sufficient clearance around the panel for wiring and future expansion. Maintain a minimum of 6 inches of free space above, below, and on all sides. Avoid mounting near sources of electromagnetic interference, which could affect performance. Verify the mounting surface is level to prevent internal component stress. Always adhere to local codes and regulations regarding fire alarm panel placement.
Wiring Considerations
Proper wiring is crucial for the ES-200X’s functionality and reliability. Utilize the correct gauge wiring as specified in the installation guide to minimize voltage drop and ensure adequate current flow. All wiring must comply with local and national electrical codes. Employ supervised circuit wiring techniques to detect open or short circuit conditions, enhancing system integrity.
Separate fire alarm wiring from power and communication cables to prevent interference. Use shielded wiring where necessary, particularly in high-noise environments. Clearly label all wiring connections for easy identification during maintenance and troubleshooting. Ground the system properly to minimize electrical noise and ensure safety. Always disconnect power before making or modifying any wiring connections.
Connecting Addressable Devices
Addressable devices connect to the ES-200X via a single pair of wires, simplifying installation and reducing wiring costs. Each device requires a unique address programmed using SWIFT Tools software. Ensure proper polarity when connecting devices – typically, red is positive and black is negative. Devices are daisy-chained, meaning the wiring runs from panel to device, then from device to device.
Maintain the loop’s integrity by avoiding splices and using approved wiring connectors. The maximum loop length is dependent on the wiring gauge and device quantity; consult the manual for specifics. After wiring, use SWIFT Tools to auto-discover devices or manually assign addresses. Verify device communication and functionality through the software’s testing features.

Programming and Configuration
Utilize SWIFT Tools software, downloadable from firelite.com, to configure the ES-200X. This software enables address assignment and system customization for optimal performance.
Using SWIFT Tools
SWIFT Tools is the primary software application for programming, diagnostics, and overall configuration of the Fire-Lite ES-200X Fire Alarm Control Panel (FACP) and its associated devices; This powerful utility, freely available for download from the official firelite.com website, provides a user-friendly interface for technicians to efficiently manage system parameters.
Through SWIFT Tools, users can define device addresses, customize zone configurations, establish alarm and trouble sensitivities, and perform comprehensive system testing. The software supports direct connection to the ES-200X via a USB port, facilitating rapid data transfer and real-time monitoring. Regular software updates are released to enhance functionality and compatibility, ensuring optimal system performance and adherence to the latest industry standards. Detailed documentation and support resources are also available online to assist users in mastering the capabilities of SWIFT Tools;
Programming Addressable Devices
Addressable devices connected to the ES-200X FACP require specific programming to ensure proper functionality and integration within the fire alarm system. This process is primarily accomplished using SWIFT Tools software, connected to the control panel via a USB interface. Each device must be assigned a unique address within the system’s capacity of 198 addressable points (99 detectors and 99 modules).
Programming involves defining the device type (detector, module, etc.), sensitivity levels, and associated zone assignments. Careful attention must be paid to ensure correct configuration, as improper programming can lead to false alarms or system failures. SWIFT Tools provides detailed prompts and validation checks to minimize errors. Refer to the individual data sheets for each compatible addressable device for specific programming parameters and recommendations.
Network Configuration
The ES-200X FACP supports network connectivity, enabling remote monitoring, control, and diagnostics. Network configuration is managed through SWIFT Tools software, allowing technicians to establish communication pathways between the panel and central monitoring stations or other networked devices. This typically involves assigning a unique IP address to the panel and configuring communication protocols.
Proper network setup is crucial for reliable off-site alarm reporting and system management. Security considerations, such as password protection and encryption, should be implemented to prevent unauthorized access. Detailed network diagrams and documentation are recommended for complex installations. Refer to the SWIFT Tools documentation for specific instructions on configuring network settings and troubleshooting connectivity issues.

System Operation
The ES-200X operates in normal, alarm, and trouble modes, providing clear indication of system status. It responds to addressable device activations promptly and reliably.
Normal Operation Mode
During normal operation, the ES-200X continuously monitors all connected addressable devices – detectors and modules – for any changes in status. The control panel’s processor diligently performs self-diagnostics, ensuring all circuits and components are functioning correctly. A steady green LED typically indicates a normal, ready state.
The system actively communicates with each device, verifying its presence and operational capability. Any discrepancies or loss of communication are immediately flagged as a potential trouble condition. The user interface displays the current system status, including the number of online devices and any pre-existing trouble conditions. The ES-200X is designed for reliable, 24/7 monitoring, providing peace of mind and swift response capabilities.
Alarm Indication and Response
Upon detecting an alarm condition – initiated by a smoke detector, pull station, or module – the ES-200X immediately activates its audible and visual alarm notifications. A prominent red LED illuminates on the control panel, and the system initiates pre-programmed alarm sequences. These sequences can include activating horns, strobes, and relay outputs to notify occupants and alert emergency services.
The panel displays the specific zone and device initiating the alarm, providing crucial information for rapid response. Simultaneously, the ES-200X’s communicator transmits an alarm signal to a central monitoring station. Detailed event logging captures all alarm activity, aiding in post-incident analysis. The system prioritizes life safety, ensuring swift and effective notification during emergencies.
Trouble Conditions and Diagnostics
The ES-200X incorporates comprehensive trouble detection and diagnostic capabilities. It continuously monitors the system for faults, including ground faults, open circuits, and low battery conditions. When a trouble condition arises, a yellow LED illuminates on the control panel, and a specific trouble message is displayed, pinpointing the issue’s location.
Utilizing SWIFT Tools software, technicians can access detailed diagnostic information, including device status, loop resistance, and communication errors. This facilitates efficient troubleshooting and minimizes downtime. The system differentiates between critical and non-critical troubles, prioritizing urgent issues. Regular testing and maintenance, guided by the panel’s diagnostics, ensure reliable system operation and compliance with safety standards.

Wireless Integration
The ES-200X seamlessly integrates with Fire-Lite’s wireless devices, utilizing a wireless gateway configured via SWIFT Tools for enhanced system flexibility and coverage.
Compatible Wireless Devices
The Fire-Lite ES-200X system demonstrates compatibility with a range of wireless devices, expanding installation options and simplifying retrofits. Specifically, the system supports WAV-RL, WAV-WL, WAV-CRL, and WAV-CWL LiteSpeed Intelligent AV devices. These devices offer reliable wireless communication and are designed for easy integration into existing or new Fire-Lite systems.
Utilizing these wireless components allows for cost-effective installations, particularly in situations where running traditional wiring is challenging or impractical. The wireless devices are programmed and diagnosed using SWIFT Tools, available for download from firelite.com, ensuring seamless configuration and monitoring. Always refer to the latest compatibility documentation for a complete and up-to-date list of supported wireless devices.
Wireless Gateway Configuration
Configuring the wireless gateway for the ES-200X is primarily achieved through SWIFT Tools, a powerful programming and diagnostic utility accessible via a PC’s USB port. This software facilitates a streamlined setup process, allowing technicians to easily integrate wireless devices into the fire alarm system. The gateway requires careful configuration to ensure reliable communication and optimal performance.
Key configuration steps involve assigning a unique address to the gateway, defining communication parameters, and establishing a secure network connection. SWIFT Tools provides a user-friendly interface for these tasks, guiding users through each step. Regularly checking the gateway’s status and logs within SWIFT Tools is crucial for maintaining system integrity and promptly addressing any potential issues.
Wireless Signal Strength Considerations
Maintaining optimal wireless signal strength is paramount for reliable operation of the ES-200X system with integrated wireless devices. Several factors can influence signal quality, including physical obstructions like walls and metal structures, as well as interference from other wireless sources. Regular site surveys are recommended to identify potential weak spots and areas of interference.
Proper placement of wireless devices and the gateway is crucial. Avoid locating devices near sources of interference or behind substantial obstructions. Utilizing a signal strength meter within SWIFT Tools allows technicians to assess signal levels at each device location. Repeaters may be necessary in larger facilities or areas with significant signal attenuation to ensure consistent and dependable communication throughout the system.

Maintenance and Troubleshooting
Regular inspections and prompt troubleshooting are vital for sustained system reliability. Utilize SWIFT Tools for diagnostics, and refer to documentation for common issues and firmware updates.
Regular Inspection Procedures
Consistent inspection is crucial for maintaining the Fire-Lite ES-200X’s reliability. Monthly visual inspections should verify the control panel’s display is clear and free of trouble alarms. Check all wiring connections for tightness and integrity, ensuring no damage is present.
Battery functionality must be tested semi-annually to confirm adequate backup power during outages. Functional testing of initiating devices – smoke detectors, pull stations – should occur annually, documenting results.
Inspect all addressable devices, verifying proper communication with the panel via SWIFT Tools. Review the event log for any unusual activity or recurring issues. Keep a detailed record of all inspections and maintenance performed, adhering to NFPA 72 guidelines for comprehensive fire alarm system upkeep.
Common Troubleshooting Steps
When facing issues with the ES-200X, begin with basic checks. Verify power supply connections and battery voltage. Utilize SWIFT Tools to examine the event log for specific error codes, providing clues to the problem’s source.
If a device is in trouble, confirm its address is correctly programmed and that wiring is secure. Communication issues often stem from wiring faults or device incompatibility.
For alarm activations, investigate initiating devices and review recent activity. If problems persist, consult the detailed documentation or contact Honeywell Building Solutions for expert support. Remember to document all troubleshooting steps taken and their outcomes for future reference and efficient problem resolution.
Firmware Updates
Maintaining current firmware on your ES-200X is crucial for optimal performance and access to the latest features. Firmware updates are typically available for download from the official Fire-Lite website (firelite.com) and are applied using SWIFT Tools software.
Before initiating an update, carefully review the release notes to understand the changes and any potential compatibility considerations.
Ensure a stable power supply during the update process to prevent interruption and potential damage to the control panel. Follow the on-screen instructions within SWIFT Tools precisely. After completion, verify the new firmware version is correctly installed and perform a system test to confirm proper functionality. Regular updates enhance system security and reliability.

Compatibility and Replacement
The ES-200X directly replaces the MS-9200UDLS and supports a wide range of addressable devices; consult data sheets on firelite.com for specifics.
Replacement for MS-9200UDLS
The Fire-Lite ES-200X is specifically designed as a direct replacement for the MS-9200UDLS fire alarm control panel. This upgrade path simplifies modernization efforts, minimizing disruption during system upgrades. Existing wiring and many previously installed addressable devices are often compatible, reducing overall installation costs and time.
However, a thorough review of device compatibility is always recommended, referencing the latest data sheets available on the Fire-Lite website (firelite.com). While the ES-200X maintains similar functionality, programming and configuration may require adjustments using SWIFT Tools. The pre-installed communicator in the ES-200X offers enhanced connectivity options compared to the MS-9200UDLS, streamlining communication with monitoring stations.
Compatible Addressable Devices
The ES-200X supports a wide range of Fire-Lite addressable devices, including detectors and modules, up to a maximum of 198 devices (99 detectors and 99 modules). Compatible devices include those from the LiteSpeed Intelligent AV series, such as WAV-RL, WAV-WL, WAV-CRL, and WAV-CWL.
For a comprehensive and up-to-date list, consult the official Fire-Lite documentation and data sheets available for download at firelite.com. These resources detail specific model numbers and compatibility notes. Ensure devices are programmed correctly using SWIFT Tools for optimal performance and integration with the ES-200X FACP. Regularly check for firmware updates to maintain compatibility and access the latest features.

Data Sheets and Documentation
Comprehensive documentation for the Fire-Lite ES-200X is readily available from Fire-Lite’s official website, firelite.com. Key documents include the installation manual (DF-60957:D, as of March 27, 2023), providing detailed wiring diagrams and mounting instructions.
Data sheets outline specifications for compatible addressable devices, ensuring proper system integration. SWIFT Tools software documentation assists with programming and diagnostics. Regularly check for updated revisions of these documents, as Fire-Lite frequently releases updates to reflect product enhancements and address potential issues. Accessing these resources is crucial for correct installation, configuration, and maintenance of the ES-200X system.